REALTIME CONTROL
RV229 Anemometer Adapter
Users Manual
3. Real time pulse frequency connection




The RV229 can output speed and/or direction in pulse frequency form.

Connect the transducer to the RV229.

Use a DE9/DB9 plug to connect to the RV229, and on this:

Use shielded cable to connect the Speed and Direction pins to the DCS, PLC or datalogger I/O module. Connect the shield from V- to the - terminal on the I/O module. Connect the core from Speed and/or Direction to corresponding + terminal(s) on the I/O module.

Leave the Serial in and Serial out pins floating, ie. connect nothing to them.

Connect a battery or power supply capable of delivering in the range 3.7 V DC to 30.0 V DC @ 4 mA to V- and V+.

Connect this plug to the RV229.

The RV229's LED should flash once per rotor revolution.

Index